faxrunq

Markus Welters (markus@welters.de)
Sun, 5 Jul 1998 20:52:01 +0200


At 20:09 05.07.98 , Gert Doering wrote:
>Hi,
>
>Markus Welters wrote:
>> >> after sending the first fax with 'faxrunq' my modem needs some idle
>> >> seconds. For default 'faxrunq' tries to send the second one directly
after
>> >> the first. That's the point my ELSA Mircolink doesn't like. Where can=
 i
>> >> set a pause?
>[..]
>>=20
>> I think, it a german problem named "Wahlsperre".
>> These modems only dial out every 60 seconds or so.
>
>Hmmm. I thought that this is only valid after a failed call?  Anyway,
>look at how the USR Courier does this - in case of "Wahlsperre", an
>ATD command is answered first with "WAITING", and after the time is over,
>the dial command is done.  That way, you obey the rules without hurting
>programs.

If I remember the old mailbox days right, these behaviors occured:

- After a failed call some modems answered "Call barred" or "Call delayed"
There had to be no dial command within the next 60 or 90 second, otherwise
the time was extended.

- Other braindead modems disabled 60 seconds after each attempt the dialing
function.

- Modem simply answered "Busy" (i.e. Zyxel 1496 EG, if I remember correct)

But all modem manufacturers had a, in these days, non-documented command to
switch this off.
(i.e. Creatix: at%TCB)

Searching Fireball for "+Modem +Wahlsperre" I found:

http://members.aol.com/jtrede/wahlsp.html

Elsa GmbH       =20
Microlink 28800 TL    alle         ATS31=3D128 oder ATS31=3D64
Microlink 28800 TQV   alle         ATS31=3D128 oder ATS31=3D64
Microlink 33600 TQV   alle         ATS31=3D128 oder ATS31=3D64
Microlink 14.4 TL                  ATS31=3D114*W
Microlink 14.4 PC                  ATS31=3D114*W

>
>But you *might* be right...
>
>> Try to find out the init string to disable this behavior.
>
>This might be another approach, yes.

I meant: "Try to find the string to disable "Wahlsperre"

And burn it into the modem with at&w or at&w0

-
Mit freundlichen Gr=FC=DFen

Markus Welters

----
Welters Datentechnik   Grafenberger Allee 81  40237 Duesseldorf
Telefon +49-211-9660093  GSM 0172-2007477   Fax +49-211-9660091