Bizarre problem with Multiech/fax reception
Amadeu Pi (AmadeuP@santiveri.es)
Thu, 15 Apr 1999 09:22:20 +0200
Hi all,
I am using this option with my multitech modems and it works like a
charm.
Amadeu
> -----Original Message-----
> From: Marc SCHAEFER [mailto:schaefer@alphanet.ch]
> Sent: Wednesday, April 14, 1999 6:00 PM
> To: mgetty@greenie.muc.de
> Subject: Re: Bizarre problem with Multiech/fax reception
>
>
> Marc SCHAEFER <schaefer@alphanet.ch> wrote:
> > If yes, I will tell the guy to browse the manual :)
>
> Well, indeed, in the mgetty info documentation, under Multitech, I
> found this:
>
> BUT: There seems to be a way to tell the modem to behave like a
> Rockwell one and use the "wrong" byte order. Carlos Fonseca found the
> following text on ftp.multitech.com:
>
> Function Command Description
>
> PROCESS +FRBOR Maintaining compatibility with
> DATA IN Rockwell Class 2 chip
> set for fax data
> DIRECT OR reception .
> REVERSE ORDER FRBOR=0 - Process
> received fax data in
> direct order.
> FRBOR=1 - Process
> received fax data in
> reverse order.
>
> So, to not require special flags for the fax conversion
> utilities, this
> can probably be used.
>
>