RAS Server

Gert Doering (gert@greenie.muc.de)
Thu, 1 Apr 1999 09:32:25 +0200


Hi,

On Wed, Mar 31, 1999 at 02:38:28PM -0600, Joddy Grider wrote:
> I have a Suse based RAS server using an Equinox modem pool. The problem I am
> having is the first conection goes fine but the next connection takes over
> control of  session of the first login. Any help would be greatly appreciated.

Sounds like the modem is not handling DCD properly, or DCD is not wired
through to the serial port.  (Thus no DCD drop upon loss of connection,
and no termination of the shell).

Also, it sounds like the modem is set to auto-answer, which is a big
no-no.

gert
-- 
USENET is *not* the non-clickable part of WWW!
                                                           //www.muc.de/~gert/
Gert Doering - Munich, Germany                             gert@greenie.muc.de
fax: +49-89-35655025                        gert.doering@physik.tu-muenchen.de